Manifold with Adaptors The PVC filtered water discharge manifold comes with a fitted adaptor for each filter leaf, an end plug and flange. The adaptors and end plug are supplied attached. The flange is supplied loose. Manifold size is selected for each project, based on maximum system flow.
Leaf Clamp Assembly The leaf clamp assembly assures precise spacing and individual leaf removal using permanent positioning clamps mounted on angles. All metal parts are stainless steel including mounting clips, nuts, bolts and lags.
Manifold Support Clamps Manifold support clamps have adjustable legs suitable for sloped bottom tanks. One manifold support clamp is recommended for every eight leaves in a filter bank. Fiberglass is standard. Stainless steel is also available.
GENERAL NOTES Tank laminate is constructed of alternate layers of fiberglass fabric and resin.
A “C-glass” surfacing veil shall be used.
Resin System shall be a general purpose resin suitable for the service conditions.
Construction shall be in the hand lay-up method in accordance with NBS PS 15-69 Voluntary Product Standard.
Flanges shall be drilled to 150# ASNI standard.
Dimensional variations shall be plus or minus 1/8″ for all dimensions.
Drain and overflow connections to be standard PVC socket weld fittings.
Tank requires full bottom support.
Flange bolt holes shall straddle north-south centerlines. Nozzle “B” must have minimum height of 12″, maximum height no greater than 34″. Nozzle “B” can also be located on the 72″ side of the tank if desired. Baffle must be between inlet port and filter leaves.
Bottom Outlet – Large Leaf
GENERAL NOTES Tank laminate is constructed of alternate layers of fiberglass fabric and resin. A “C-glass” surfacing veil shall be used. Resin System shall be a general purpose resin suitable for the service conditions. Construction shall be in the hand layup method in accordance with NBS PS 15-69 Voluntary Product Standard. Flanges shall be drilled to 150# ASNI standard. Dimensional variations shall be plus or minus 1/8″ for all dimensions. Drain and overflow connections to be standard PVC socket weld fittings. Tank requires full bottom support. Flange boltholes shall straddle north-south centerlines. Nozzle “B” must have minimum height of 12″, maximum height no greater than 34″. Nozzle “B” can also be located on the 72″ side of the tank if desired. Baffle must be between inlet port and filter leaves.
Edge Outlet – Small Leaf
GENERAL NOTES Tank laminate is constructed of alternate layers of fiberglass fabric and resin. A “C-glass” surfacing veil shall be used. Resin System shall be a general purpose resin suitable for the service conditions. Construction shall be in the hand lay-up method in accordance with NBS PS 15-69 Voluntary Product Standard. Flanges shall be drilled to 150# ASNI standard. Dimensional variations shall be plus or minus 1/8″ for all dimensions. Drain and overflow connections to be standard PVC socket weld fittings. Tank requires full bottom support. Flange bolt holes shall straddle north-south centerlines. Nozzle “B” must have minimum height of 12″, maximum height no greater than 16″. Nozzle “B” can also be located on the 72″ side of the tank if desired. Baffle must be between inlet port and filter leaves.
Bottom Outlet – Small Leaf
GENERAL NOTES Tank laminate is constructed of alternate layers of fiberglass fabric and resin. A “C-glass” surfacing veil shall be used. Resin System shall be a general purpose resin suitable for the service conditions. Construction shall be in the hand layup method in accordance with NBS PS 15-69 Voluntary Product Standard. Flanges shall be drilled to 150# ASNI standard. Dimensional variations shall be plus or minus 1/8″ for all dimensions. Drain and overflow connections to be standard PVC socket weld fittings. Tank requires full bottom support. Flange boltholes shall straddle north-south centerlines. Nozzle “B” must have minimum height of 12″, maximum height no greater than 16″. Nozzle “B” can also be located on the 72″ side of the tank if desired. Baffle must be between inlet port and filter leaves.
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish.AcceptRead More
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.