“T” Style Standard Strainers

“T” STYLE BASKET STRAINERS

 

Inlet Dia. Outlet Dia. A B C D E
4″ 4″ 9-1/4″ 14″ 12″ 21 1/2″ 7 1/4″
6″ 6″ 11 1/4″ 16″ 15 1/2″ 25 1/4″ 9 1/4″
8″ 8″ 13 1/4″ 20″ 17 1/2″ 30 1/4″ 11 1/4″
10″ 10″ 15 1/4″ 24″ 21 1/2″ 34 3/4″ 13 1/2″
12″ 12″ 17 1/4″ 26″ 23″ 37 1/2″ 15 3/4″
14″ 14″ 23 1/4″ 32″ 31″ 48″ 21 3/4″
16″ 16″ 23 1/4″ 32″ 31″ 48″ 21 3/4″
18″ 18″ 23 1/4″ 32″ 31″ 48″ 21 3/4″
20″ 20″ 23 1/4″ 32″ 32 1/2″ 48″ 21 3/4″

 

MATERIALS OF CONSTRUCTION
1. Strainer Body: Fiberglass reinforced plastic construction with C-veil liner and isophthalic polyester resin.
2. Flanges: 3/4″ thick w/150 lb. drilling patterns.
3. Lid: 4″-12″ Clear acrylic, 14″-18″ FRP with clear acrylic view port
4. O-Ring: Ethylene Propylene
5. Hand Knobs:  ABS w/Bronze Inserts
6. Basket:  316 stainless steel v-wire w/ 3/16″ square openings (62% open area)
7. Pressure Rating: 50 psi

Reducing Pool Strainer

FO SERIES REDUCING STRAINER SIZE & DIMENSION TABLE

Inlet
Diameter
Outlet
Diameter
A B B1 C1 C2 D E
4″ 3″ 9-1/4″ 16-5/8″ 20-5/8″ 12″ 12-1/2″ 21-1/2″ 7-1/4″
4″ 2-1/2″ 9-1/4″ 16-5/8″ 20-5/8″ 12″ 12-3/4″ 21-1/2″ 7-1/4″
4″ 2″ 9-1/4″ 16-5/8″ 20-5/8″ 12″ 13″ 21-1/2″ 7-1/4″
6″ 5″ 11-1/4″ 17-5/8″ 20-5/8″ 15-1/2″ 16″ 25-1/4″ 9-1/4″
6″ 4″ 11-1/4″ 17-5/8″ 20-5/8″ 15-1/2″ 16-1/2″ 25-1/4″ 9-1/4″
6″ 3″ 11-1/4″ NA 20-5/8″ 15-1/2″ 17″ 25-1/4″ 9-1/4″
6″ 2-1/2″ 11-1/4″ NA 20-5/8″ 15-1/2″ 17-1/4″ 25-1/4″ 9-1/4″
8″ 6″ 13-1/4″ 23-1/2″ 31″ 17-1/2″ 18-1/2″ 30-1/4″ 11-1/4″
8″ 5″ 13-1/4″ 23-1/2″ 31″ 17-1/2″ 19 30-1/4″ 11-1/4″
8″ 4″ 13-1/4″ NA 31″ 17-1/2″ 19-1/2″ 30-1/4″ 11-1/4″
8″ 3″ 13-1/4″ NA 31″ 17-1/2″ 20″ 30-1/4″ 11-1/4″
10″ 3″ 15-1/4″ 28-3/4″ 38-3/4″ 21-1/2″ 22-1/2″ 34-3/4″ 13-1/2″
10″ 8″ 15-1/4″ NA 38-3/4″ 21-1/2″ 23-1/2″ 34-3/4″ 13-1/2″
10″ 6″ 15-1/4″ NA 38-3/4″ 21-1/2″ 24″ 34-3/4″ 13-1/2″
10″ 5″ 15-1/4″ NA 38-3/4″ 21-1/2″ 24-1/2″ 34-3/4″ 13-1/2″
12″ 10″ 17-1/4″ 31-1/2″ 41-1/2″ 23″ 24″ 37-1/2″ 15-3/4″
12″ 8″
17-1/4″ NA 41-1/2″ 23″ 25″ 37-1/2″ 15-3/4″
12″ 6″
17-1/4″ NA 41-1/2″ 23″ 26″ 37-1/2″ 15-3/4″
12″ 5″
17-1/4″ NA 41-1/2″ 23″ 26-1/2″ 37-1/2″ 15-3/4″
14″  12″  23-1/4″  31-1/2″  52″  31″ 32″ 48″ 21-3/4″
14″  10″  23-1/4″  NA  52″  31″ 33″ 48″ 21-3/4″
14″  8″  23-1/4″  NA  52″  31″ 34″ 48″ 21-3/4″
14″  6″  23-1/4″  NA  52″  31″ 35″ 48″ 21-3/4″
16″  14″  23-1/4″  42  52″  31″ 32″ 48″ 21-3/4″
16″  12″  23-1/4″  NA  52″  31″ 33″ 48″ 21-3/4″
16″  10″  23-1/4″  NA  52″  31″ 34″ 48″ 21-3/4″
16″  8″  23-1/4″  NA  52″  31″ 35″ 48″ 21-3/4″
18″ 16″ 23-1/4″ 42″ 52″ 31″ 32″ 48″ 21-3/4″
18″ 14″
23-1/4″ NA 52″ 31″ 33″ 48″ 21-3/4″
18″ 12″
23-1/4″ NA 52″ 31″ 34″ 48″ 21-3/4″
18″ 10″
23-1/4″ NA 52″ 31″ 35″ 48″ 21-3/4″
 20″  18″  23-1/4″  42″ 52″  32 1/2″  33 1/2″  48″  21-3/4″
 20″  16″  23-1/4″  NA 52″  32 1/2″  34 1/2″  48″  21-3/4″
 20″  14″  23-1/4″  NA 52″  32 1/2″  35 1/2″  48″  21-3/4″
 20″  12″  23-1/4″  NA 52″  32 1/2″  36 1/2″  48″  21-3/4″

Standard Pool Strainer

FO SERIES BASKET STRAINER SIZE & DIMENSION TABLE

Inlet
Diameter
Outlet
Diameter
A B C D E F G
4″ 4″ 9-1/4″ 16-5/8″ 12″ 21-1/2″ 7-1/4″ 4-7/8″ 14-1/2″
6″ 6″ 11-1/4″ 17-5/8″ 15-1/2″ 25-1/4″ 9-1/4″ 6-7/8″ 18″
8″ 8″ 13-1/4″ 23-1/2″ 17-1/2″ 30-1/4″ 11-1/4″ 8-7/8″ 22″
10″ 10″ 15-1/4″ 28-3/4″ 21-1/2″ 34-3/4″ 13-1/2″ 10-7/8″ 27″
12″ 12″ 17-1/4″ 31-1/2″ 23″ 37-1/2″ 15-3/4″ 12-3/4″ 29-1/2″
14″ 14″ 23-1/4″ 42″ 31″ 48″ 21-3/4″ 18-1/2″ 39-1/2″
16″ 16″ 23-1/4″ 42″ 31″ 48″ 21-3/4″ 18-1/2″ 39-1/2″
18″ 18″ 23-1/4″ 42″ 31″ 48″ 21-3/4″ 18-1/2″ 39-1/2″
20″ 20″ 23-1/4″ 42″ 31″ 48″ 21-3/4″ 18-1/2″ 39-1/2″

 

Size Opening Size
(Square)
Basket Free Area
Sq. In.
Ratio-Free Area
to Pipe Area
Weight (lbs)
4″ 3/16″ 116 9.2 45
6″ 3/16″ 211 7.5 47
8″ 3/16″ 327 6.5 45
10″ 3/16″ 498 6.3 90
12″ 3/16″ 627 5.5 110
14″ 3/16″ 1210 7.9 340
16″ 3/16″ 1210 6 360
18″ 3/16″ 1210 4.7 380
20″ 3/16″ 1210 3.9 405

Tanked Package D.E. Systems

Edge Outlet – Large Leaf

GENERAL NOTES
Tank laminate is constructed of alternate layers of fiberglass fabric and resin.
A “C-glass” surfacing veil shall be used.
Resin System shall be a general purpose resin suitable for the service conditions.
Construction shall be in the hand lay-up method in accordance with NBS PS 15-69 Voluntary Product Standard.
Flanges shall be drilled to 150# ASNI standard.
Dimensional variations shall be plus or minus 1/8″ for all dimensions.
Drain and overflow connections to be standard PVC socket weld fittings.
Tank requires full bottom support.
Flange bolt holes shall straddle north-south centerlines.
Nozzle “B” must have minimum height of 12″, maximum height no greater than 34″. Nozzle “B” can also be located on the 72″ side of the tank if desired. Baffle must be between inlet port and filter leaves.


Bottom Outlet – Large Leaf

GENERAL NOTES
Tank laminate is constructed of alternate layers of fiberglass fabric and resin. A “C-glass” surfacing veil shall be used.
Resin System shall be a general purpose resin suitable for the service conditions.
Construction shall be in the hand layup method in accordance with NBS PS 15-69 Voluntary Product Standard.
Flanges shall be drilled to 150# ASNI standard.
Dimensional variations shall be plus or minus 1/8″ for all dimensions.
Drain and overflow connections to be standard PVC socket weld fittings.
Tank requires full bottom support.
Flange boltholes shall straddle north-south centerlines.
Nozzle “B” must have minimum height of 12″, maximum height no greater than 34″. Nozzle “B” can also be located on the 72″ side of the tank if desired. Baffle must be between inlet port and filter leaves.


Edge Outlet – Small Leaf



GENERAL NOTES

Tank laminate is constructed of alternate layers of fiberglass fabric and resin.
A “C-glass” surfacing veil shall be used.
Resin System shall be a general purpose resin suitable for the service conditions.
Construction shall be in the hand lay-up method in accordance with NBS PS 15-69 Voluntary Product Standard.
Flanges shall be drilled to 150# ASNI standard.
Dimensional variations shall be plus or minus 1/8″ for all dimensions.
Drain and overflow connections to be standard PVC socket weld fittings.
Tank requires full bottom support.
Flange bolt holes shall straddle north-south centerlines.
Nozzle “B” must have minimum height of 12″, maximum height no greater than 16″. Nozzle “B” can also be located on the 72″ side of the tank if desired. Baffle must be between inlet port and filter leaves.


Bottom Outlet – Small Leaf


GENERAL NOTES
Tank laminate is constructed of alternate layers of fiberglass fabric and resin.

A “C-glass” surfacing veil shall be used.
Resin System shall be a general purpose resin suitable for the service conditions.
Construction shall be in the hand layup method in accordance with NBS PS 15-69 Voluntary Product Standard.
Flanges shall be drilled to 150# ASNI standard.
Dimensional variations shall be plus or minus 1/8″ for all dimensions.
Drain and overflow connections to be standard PVC socket weld fittings.
Tank requires full bottom support.
Flange boltholes shall straddle north-south centerlines.
Nozzle “B” must have minimum height of 12″, maximum height no greater than 16″. Nozzle “B” can also be located on the 72″ side of the tank if desired. Baffle must be between inlet port and filter leaves. 