Specification
pH Range 4.0 – 10.0
pH Display Resolution 0.1
ORP Range 500 – 1000 mV
ORP Display Resolution – 2mV
Chlorine/ppm Range 0.1 – 12.0+ ppm
Chlorine/ppm Display Resolution 0.1 ppm
Temperature Range 60- 120 F
Temperature Resolution 1 F
Input Power – 120 VAC 60 Hz, less than 1 Amp, excluding pumps, 3 wire grounded plug GFCI source required
Output Power – (2) switched standard 3-wire grounded outlets, 120 VAC 60 Hz, 6 Amps cumulative, fused
Display – 2 x 16 character digital display, multi-color flashing LED indicator
Enclosure – PVC NEMA 12 with hinged cover and lockable hasp
Size – 10.5” x 8.9” x 6.0”
Weight 5.5lbs
Printer 40/80 column thermal dot matrix
Modem 56k Baud internal modem
Communication Software Sitelink ™ PC based communication software
Selectable Parameters included:
- Ideal pH, ORP, chlorine/ppm, Br and temperature settings
- Upper and lower limits for acceptable operating range
- Mixing times from O – 99 minutes
- Chemical dosing periods from O – 99 minutes
- pH dosing either acid or base
- Proportionally pulsed and manual chemical dosing
- Lag compensation with DPMC control
- Safety lockouts for excessive or insufficient feed
- Audible and visual alarms for non-correctable conditions
- Programmable Super-Chlorination